Hi all,

My system is a Dell 2850:
SunOS  5.11 snv_70b i86pc i386 i86pc

I have 2 Emulex fibre cards with 10 8GB drives attached on a EMC SYMMETRIX 5671.
I can see the drives properly through commands:

format
luxadm probe
fcinfo logical-unit

Also, "mpathadm show mpath-support libmpscsi_vhci.so" shows SYMMETRIX 5671 
support.
(I had to modify the /kernel/drv/scsi_vhci.conf file for that to show up)

However, multipath does not seem to work. It is enabled in /kernel/drv/fp.conf .

"mpathadm list lu" Returns nothing. No errors and nothing is logged.

"luxadm display /dev/rdsk/c2t5006048ACCC8AE00d29s2" shows:

DEVICE PROPERTIES for disk: /dev/rdsk/c2t5006048ACCC8AE00d29s2
  Vendor:               EMC
  Product ID:           SYMMETRIX
  Revision:             5671
  Serial Num:           900600068330
  Unformatted capacity: 8631.562 MBytes
  Read Cache:           Enabled
    Minimum prefetch:   0x0
    Maximum prefetch:   0xffff
  Device Type:          Disk device
  Path(s):

  /dev/rdsk/c2t5006048ACCC8AE00d29s2
  /devices/[EMAIL PROTECTED],0/pci8086,[EMAIL PROTECTED]/pci8086,[EMAIL 
PROTECTED]/pci10df,[EMAIL PROTECTED]/[EMAIL PROTECTED],0/[EMAIL 
PROTECTED],1d:c,raw
   Controller           /dev/cfg/c2
    Device Address              5006048accc8ae00,1d
    Host controller port WWN    10000000c955cc67
   Controller           /dev/cfg/c3
    Device Address              5006048accc8ae0f,21
    Host controller port WWN    10000000c9290dd1

And I get this error on all drives's: 

mpathadm show lu /dev/rdsk/c3t5006048ACCC8AE0Fd41s0
Error: Logical-unit /dev/rdsk/c3t5006048ACCC8AE0Fd41s0 is not found.

Any ideas? 

Thanks,
Ashay
 
 