Tim,
First off, I'd just like to thank you for publishing this code
review, and allowing the storage community a chance to comment
on your proposed changes, before the 'putback'.

I've only had time for a quick glance over the code, but
basically I see you are splitting the 'S6 Freeing' state into two
separate states, which you are naming 'S6-IN' and 'S6-AIO'.

I hope to have the time for a closer look over the next few days,
and then to be able to give some feedback.

Oh and it's also your first post to the OpenSolaris storage forum!  
Well done :-)
Best Regards
Nigel Smith
 
 