Hi,

   x4150, S10U4 + patches, 2530 array, host dual SAS connected (Sun's SAS card) 
each link to different array's controller.

I can see disks twice, which is ok.
So I enabled MPxIO on all controllers (internal disks and SAS card for 2530 
connectivity are both managed by MPT driver) and I can get local disks under 
MPxIO but I can't get 2530 disks under MPxIO. Kernel is 127112-08 and patch 
125082-14 is also installed.

I've also tried to disable MPxIO for internal disks so in my mpt.conf I have:

mpxio-disable="no";
name="mpt" parent="/[EMAIL PROTECTED],0/pci8086,[EMAIL 
PROTECTED]/pci1000,[EMAIL PROTECTED]" unit-address="0" mpxio-disable="yes"; 

Unfortunately local disks are still under MPxIO and 2530's LUNs are not.

I changed mpt.conf to:
mpxio-disable="no";
#name="mpt" parent="/[EMAIL PROTECTED],0/pci8086,[EMAIL 
PROTECTED]/pci1000,[EMAIL PROTECTED]" unit-address="0" mpxio-disable="yes";
name="mpt" parent="/[EMAIL PROTECTED],0/pci8086,[EMAIL PROTECTED]" 
unit-address="0" mpxio-disable="yes"; 

and this time local disks are no longer under MPxIO but neither are 2530's luns.
Additionally in /var/adm/messages I got:

WARNING: [EMAIL PROTECTED]: mpt.conf properties not merged


I have a similar config on v490/SPARC with 2530 and it works (however there are 
other issues).

Any idea how to get MPxIO with 2530 on x4150 on S10U4 to work?

 

-- 
Robert Milkowski
http://milek.blogspot.com
 
 
This message posted from opensolaris.org
_______________________________________________
storage-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/storage-discuss

Reply via email to