to clarify I currently use mpxio with clariion raid5 luns in failover
mode 1, so why do I need to use failover mode 4 (ALUA) for raid6 luns?

On Thu, Jun 3, 2010 at 3:25 PM, Max Levine <max...@gmail.com> wrote:
> Is there a way to make it work without enabling ALUA? I really dont
> want to do that.
>
> On Thu, Jun 3, 2010 at 3:23 PM, Torrey McMahon <tmcmah...@yahoo.com> wrote:
>>  On 6/3/2010 3:13 PM, Max Levine wrote:
>>>
>>> I am having a problem configuring a lun (raid-6) from EMC clariion under
>>> mpxio.
>>>
>>> the raid-6 luns have a different id than raid5 (DGC    VRAID), so I
>>> had to add the following to scsi_vhci.conf:
>>>
>>> device-type-scsi-options-list =
>>> "DGC     VRAID", "symmetric-option";
>>>
>>> symmetric-option = 0x1000000;
>>
>> Trying to fake out mpxio by telling it that the Clariion is a symmetric
>> array is a bad idea. Put it into ALUA mode, take out the bits above, and it
>> should work out of the box.
>> _______________________________________________
>> storage-discuss mailing list
>> storage-discuss@opensolaris.org
>> http://mail.opensolaris.org/mailman/listinfo/storage-discuss
>>
>
_______________________________________________
storage-discuss mailing list
storage-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/storage-discuss

Reply via email to