I just dont want to add a new variable in production system. Also on
Clariion ALUA is implemented by passing data through the clariion
messaging interface which is a PCI bus between the 2 SPs. I am not
sure that this bus can handle massive data flow in case of an SP
failure.

On Thu, Jun 3, 2010 at 3:37 PM, Torrey McMahon <tmcmah...@yahoo.com> wrote:
>  Probably not. Is there a particular reason ALUA is a bad thing? (This is
> starting to sound familiar....)
>
> On 6/3/2010 3:25 PM, Max Levine wrote:
>>
>> Is there a way to make it work without enabling ALUA? I really dont
>> want to do that.
>>
>> On Thu, Jun 3, 2010 at 3:23 PM, Torrey McMahon<tmcmah...@yahoo.com>
>>  wrote:
>>>
>>>  On 6/3/2010 3:13 PM, Max Levine wrote:
>>>>
>>>> I am having a problem configuring a lun (raid-6) from EMC clariion under
>>>> mpxio.
>>>>
>>>> the raid-6 luns have a different id than raid5 (DGC    VRAID), so I
>>>> had to add the following to scsi_vhci.conf:
>>>>
>>>> device-type-scsi-options-list =
>>>> "DGC     VRAID", "symmetric-option";
>>>>
>>>> symmetric-option = 0x1000000;
>>>
>>> Trying to fake out mpxio by telling it that the Clariion is a symmetric
>>> array is a bad idea. Put it into ALUA mode, take out the bits above, and
>>> it
>>> should work out of the box.
>>> _______________________________________________
>>> storage-discuss mailing list
>>> storage-discuss@opensolaris.org
>>> http://mail.opensolaris.org/mailman/listinfo/storage-discuss
>>>
>
_______________________________________________
storage-discuss mailing list
storage-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/storage-discuss

Reply via email to