Hi Jef,

Am 07.04.14 11:42, schrieb Jef Driesen:
I'm not sure if you are aware of this, but there are dive computers out there that don't have a fixed sample rate. Some (older) Oceanics support a depth based sample rate. They record a new sample whenever a certain depth threshold is exceeded. The timestamps of such samples are not regularly spaced.

True, the smarttrak data format also has a "repeat x times" if the depth does not change IIRC Fact is though, that until today, every DC data format that I have an import for does give me regular samples inside their own format, even if the computer does not specifically record one (except for the Smarttrak format, where i create x dummy samples for the "repeat x times").

if there is need for irregular sample intervals, I will be happy to adapt

Rainer
_______________________________________________
subsurface mailing list
[email protected]
http://lists.hohndel.org/cgi-bin/mailman/listinfo/subsurface

Reply via email to