More planner related issues. Switching from last stop = 3m to last stop = 6m gives a ceiling violation upon surfacing.
Tested using this example but I have seen it happen other times as well. depth, duration, runtime, gasmix 40, 2, 2, EAN27 40, 24, 26, EAN27 Last stop at 3m gives the following deco table. depth, duration, runtime 12, 5, 31 9, 2, 33 6, 2, 36 3, 11, 47 Last stop at 6m gives the following deco table, and a ceiling violation. depth, duration, runtime 12, 5, 31 9, 2, 33 6, 0, 36 6, 12, 46 NOTE. These values are from the planner window, not the saved plan. Also the transition times are shown in the final deco table, why not show them while in planner as well. //Jocke _______________________________________________ subsurface mailing list [email protected] http://lists.hohndel.org/cgi-bin/mailman/listinfo/subsurface