On 18 Nov 2014, at 15:46, Paul Sargent <[email protected]> wrote:

>> The EN13319 (European CE standard for dive computers) value is between fresh 
>> and salt and is the Predator default value. The EN13319 value corresponds to 
>> a 10m increase in depth for pressure increase of 1 bar.
> 
> Sorry to resurrect, but that last statement is patently wrong. It would be 
> 1.02 bar, which is pretty close to an atmosphere (1.01325 bar) but still not 
> 1-to-1. 

No, I was wrong. Ignore me. Gravity gets in there with it’s nearly 10, but not 
quite stuff. 1.020 kg/m³ does indeed work out to ~1 bar

I’ll shut up now.

Attachment: signature.asc
Description: Message signed with OpenPGP using GPGMail

_______________________________________________
subsurface mailing list
[email protected]
http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface

Reply via email to