"Jimmy Fox" <[EMAIL PROTECTED]> wrote: > I have a couple SunRay 150's that will only read our older smart > cards (part number 370-4328-01, there is another smaller number > under it: 35930) but not our newer ones (part number 370-4333-02, > with a smaller number under the part number: 38047)
What firmware are these units running? What release of SRSS is the server running, and are its patches up to date? > both set of cards came directly from Sun. It will read any older > card in the building but none of the newer cards. I have 10 more > 150's that have no problem reading both sets of cards. The SunRay > 150 part number is: 380-0343-01. The original Sun smartcards were Schlumberger MicroPayflex cards. At some point Schlumberger discontinued those cards so Sun switched to Payflex instead. I thought the Sun Ray 150 firmware could always read both types of cards but it's possible there was an early version that could only handle MicroPayflex, perhaps some of your 150s have that version. If that's what's going on then upgrading the firmware should take care of it. > The older cards are the ones with the Sun graphics printed on them > while the new ones are blank without the graphics. If you start a desktop in a session on one of the old cards then what does 'echo $SUN_SUNRAY_TOKEN' say in that session? What does it say in a session on one of the new cards? OttoM. __ ottomeister Disclaimer: These are my opinions. I do not speak for my employer. -- ___________________________________________________________ Sign-up for Ads Free at Mail.com http://promo.mail.com/adsfreejump.htm _______________________________________________ SunRay-Users mailing list [email protected] http://www.filibeto.org/mailman/listinfo/sunray-users