Ivar Janmaat schrieb:
Maybe I did not noticed the old firmware because utfwload does not seem
to report this information for all DTU's
bash-4.0# /opt/SUNWut/sbin/utfwload -a
3.0 janmaat 192.168.1.202 P8-FS.00144XXXX63 4.2_77_2009.10.19.17.01
bash-4.0# /opt/SUNWut/sbin/utsession -p
Token ID Registered Name Unix ID Disp State
------------------------------ -------------------- ---------- ---- -----
Bull-CP8_TB60.000077f73eXXXXef ??? janmaat 3 EAU
Bull-CP8_TB60.000077f73eXXXXfa ??? user1 7 D
MicroPayflex.5002faaf00XXXX00 ??? user2 4 D
pseudo.00144fXXXX85 ??? ??? 5 EAU
pseudo.00144fXXXXbe ??? ??? 2 EAU
I thought utfwadm -a would give me at least 3 lines with firmware
information instead of 1.
There is a known bug that utfwload does not show firmware information
for units that currently show a server policy icon (white symbol +
status code on blue background with SRSS 4.2; purple bevel 'button' with
older releases).
If you have a 'card access only' policy, so that the 'pseudo...' tokens
show an 'insert card' (60) icon, that would result in the missing
utfwload lines.
- Jörg