Ok, I think I succeeded in upgrading the firmware to the latest debugged 

version, on my SunRay2 DTU. 



I just did as Craig said, copied the firmware from the install package srs_5.2 
to the installed directory:

cp 
srs_5.2/Components/10-SRSS/Patches/solaris/sparc/146928-01/SUNWutfw/reloc/SUNWut/lib/firmware/*

/opt/SUNWut/lib/firmware

Then I just did:
# utfwload -L

and my DTU upgraded itself. Look:

# ./utquery 192.168.1.2
terminalID=00144f946b02
    terminalIPA=192.168.1.2
    model=SunRayP8
    currentAuth=b41a:508::56e3:d0fe:c0a8:102
    currentFW=4.3_146928-01_2011.06.03.14.41     <------ this is the debugged 
FW!!! :o)
    currentBarrier=430
    currentBarrierLevel=430
    currentMTU=1500
    currentLease=53786
    Subnet=255.255.255.0
    Router=192.168.1.1
    LeaseTim=53905
    DHCPServer=192.168.1.1
    INFORMServer=192.168.1.1
    FWservType=none
    speed=100F
    configMTU=1500
    dnsList=192.168.1.1
    confEnabled=1
    confNetType=DHCP
    conf.kbcountry=26
    kbcountry=26
    stopqon=0
    bandwidth=100000000
    cmdcachesize=0

Thanks guys! If I knew how to edit the wiki I could update it with install 
instructions. Or, I could post install instructions here, so someone could 
update the wiki?
_______________________________________________
SunRay-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/sunray-users

Reply via email to