Ok, I think I succeeded in upgrading the firmware to the latest debugged
version, on my SunRay2 DTU.
I just did as Craig said, copied the firmware from the install package srs_5.2
to the installed directory:
cp
srs_5.2/Components/10-SRSS/Patches/solaris/sparc/146928-01/SUNWutfw/reloc/SUNWut/lib/firmware/*
/opt/SUNWut/lib/firmware
Then I just did:
# utfwload -L
and my DTU upgraded itself. Look:
# ./utquery 192.168.1.2
terminalID=00144f946b02
terminalIPA=192.168.1.2
model=SunRayP8
currentAuth=b41a:508::56e3:d0fe:c0a8:102
currentFW=4.3_146928-01_2011.06.03.14.41 <------ this is the debugged
FW!!! :o)
currentBarrier=430
currentBarrierLevel=430
currentMTU=1500
currentLease=53786
Subnet=255.255.255.0
Router=192.168.1.1
LeaseTim=53905
DHCPServer=192.168.1.1
INFORMServer=192.168.1.1
FWservType=none
speed=100F
configMTU=1500
dnsList=192.168.1.1
confEnabled=1
confNetType=DHCP
conf.kbcountry=26
kbcountry=26
stopqon=0
bandwidth=100000000
cmdcachesize=0
Thanks guys! If I knew how to edit the wiki I could update it with install
instructions. Or, I could post install instructions here, so someone could
update the wiki?