Okay I want to see if anyone has come across this issue...  I think it might
be bug 6767357, though I want to make sure.  We have a RHEL 5 32 bit SRSS
host running srss 4.2-77 that is having a weird issue.  If a SunRay device
(we've seen this with SunRay 170 and SunRay 3i devices) has a user logged in
and power is cut and then brought back up the session will never come back,
the device just seems to reboot over and over again.  If device was at the
login screen and power is cut and returned, the login screen comes right
back without issue.

We have a second RHEL 5 32 bit server running srss 4.3-05 that does NOT have
this same issue.  I know the obvious is to patch, but we've had VERY bad
luck patching our SRSS server, where any change in the software can make
things very unstable.  We've had zero issues with our srss 4.2-77 server and
would rather stick with this version if there's a quick/dirty fix for this
issue (say replacing a single library or making a setting change or the
like). Anyone else seen this?  Thanks in advance!!


-- 