Bill Marquette wrote:
Or your missing something, I think is the correct statement.
I my previous e-mail today i got it working without carp, when I added 3 carp interfaces (I have two identical servers because I need hardware failover too.): LAN - carp0 WAN - carp1 OPT1 - carp2 During failover testing I found out that: If LAN, WAN or OPT1 was unplugged from only one server, everything worked fine. Now, when unplugging the WAN cable from second server too, (imitating hardware failover with WAN failover), then WAN link is marked down almost immediately on second router, but no wan failover occurs. Web interface and log file are showing that WAN links on both routers are down and OPT1 links are up. carp1 is in INIT state on both machines, carp0 and carp2 are masters on slave router (the one whose WAN cable was removed later). No traffic from LAN is forwarded through OPT1 :( What might be wrong? --- Veiko --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected] Commercial support available - https://portal.pfsense.org