Not allowing switch connections to an IXP switch is somewhat anachronistic. And IIRC AMS-IX also allows switch connections. Of course as an IXP operator you have to take care, i.e BPDU filtering/blocking. To make people more aware you may eben want to shut down the port if you see a BPDU frame. That's what AMS-IX currently is doing. DE-CIX just silently drops any BPDU frame received on a customer port and sends a notifocation to the customer. We would only take that port down if the customer constantly ignores our advice.
HTH, Arnold On Tuesday, August 19, 2003 5:43 PM, Andre Oppermann <[EMAIL PROTECTED]> wrote: > Steven Glogger wrote: >> >> so, who misconfigured his switch in that way? > > The question is rather who connected a switch to the TIX? Is is not > allowed precisely because of this kind of problem. For example AMSIX > is very anal about this; for a reason. > > IXEurope so far did not enforce the router port only policy, but it > seems to be time... > > At least this is only affecting those who are connected via vlan > trunking and nobody else. The TIX switch is not running STP and > thus will not shut you down. > > >> -steven >> >>> -----Original Message----- >>> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] >>> Behalf Of Michel Renfer >>> Sent: Tuesday, August 19, 2003 3:32 PM >>> To: swinog >>> Subject: [swinog] Short outage at TIX >>> >>> >>> >>> It seems, that someone did connect malconfigured equipement to the TIX >>> LAN. That also explains, why all people with Switches had loss of bgp >>> sessions due to STP algorithm... >>> >>> Aug 19 11:55:10.756 UTC: %SPANTREE-7-RECV_1Q_NON_TRUNK: Received 802.1Q >>> BPDU on >>> non trunk FastEthernet0/1 VLAN3. >>> Aug 19 11:55:10.756 UTC: %SPANTREE-7-BLOCK_PORT_TYPE: Blocking >>> FastEthernet0/1 o >>> n VLAN0003. Inconsistent port type. >>> Aug 19 12:06:28.341 UTC: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking >>> FastEthern >>> et0/1 on VLAN0003. Port consistency restored. >>> >>> Any statement from IX Europe?? >>> >>> >>> Michel Renfer >>> Network Systems Engineer >>> _______________________________________________________________________ >>> [EMAIL PROTECTED], phone: +41(0)32 327 3399, fax: +41(0)32 327 3390 >>> LAN Services AG, network engineering & 3rd level support, data networks >>> >>> "Some wise man once said: That's a great thing standards, there are so >>> many to choose from!" >>> -- unknown >>> _______________________________________________________________________ >>> >>> >>> ---------------------------------------------- >>> [EMAIL PROTECTED] Maillist-Archive: >>> http://www.mail-archive.com/swinog%40swinog.ch/ >>> >> ---------------------------------------------- >> [EMAIL PROTECTED] Maillist-Archive: >> http://www.mail-archive.com/swinog%40swinog.ch/ > ---------------------------------------------- > [EMAIL PROTECTED] Maillist-Archive: > http://www.mail-archive.com/swinog%40swinog.ch/ ---------------------------------------------- [EMAIL PROTECTED] Maillist-Archive: http://www.mail-archive.com/swinog%40swinog.ch/