Hi all
if you have used the synaser unit to talk to a gsm modem using AT commands you
may have noticed that the existing functions and procedures only handle those
AT commands to which the modem responds with 'OK' or 'ERROR'. This works fine
most of the time, however if you want to send SMS messages there is a problem
since the response you get from the 'AT+CMGS="...phone number..."' command is
'> ', at which point the modem expects you to type the message content and
submit CTRL^Z. The '> ' response is not expected by synaser and eventually the
AT command times out. I did a little digging on the code and I think I know
where I should try to make changes, but I was wondering if anyone else has
solved this before me. If you have, please let me know.
Many thanks
Petros