Hi all
if you have used the synaser unit to talk to a gsm modem using AT commands you 
may have noticed that the existing functions and procedures only handle those 
AT commands to which the modem responds with 'OK' or 'ERROR'. This works fine 
most of the time, however if you want to send SMS messages there is a problem 
since the response you get from the 'AT+CMGS="...phone number..."' command is 
'> ', at which point the modem expects you to type the message content and 
submit CTRL^Z. The '> ' response is not expected by synaser and eventually the 
AT command times out. I did a little digging on the code and I think I know 
where I should try to make changes, but I was wondering if anyone else has 
solved this before me. If you have, please let me know.

Many thanks
Petros