On Sun, Apr 14, 2013 at 10:18 AM, Reindl Harald <h.rei...@thelounge.net> wrote: > > > Am 14.04.2013 18:13, schrieb Reindl Harald: >> Am 14.04.2013 06:42, schrieb Kok: >>> You can modify systemd-readahead-done.timer, basically change: >>> >>> OnActiveSec=10s >>> >>> to whatever value you like >> >> thanks, i give it a try with 3600 seconds what should cover >> also a long coffee and mostly powner on with WOL and sync >> work-data while drive to the office > > seems like i covered a bug > the collector stops after exactly 2 minutes
src/readahead/readahead.c has: usec_t arg_timeout = 2*USEC_PER_MINUTE; so, it's by design to stop after 2 minutes. That's for a good reason, I'm not sure if changing it makes much sense - most people will never want to use non-standard values, and 2 minutes helps everyone (it could help some non-standard cases more, but it doesn't hurt anyone). Auke _______________________________________________ systemd-devel mailing list systemd-devel@lists.freedesktop.org http://lists.freedesktop.org/mailman/listinfo/systemd-devel