Hello, Le 08. 02. 18 à 14:44, Pieter Vander Vennet a écrit : > In Bruges, we have a pipeline carrying hot water (~120°C) from a waste > furnace to a hospital, a bakery, ...
For the waste furnace : power=plant for the room/building/landuse plant:source=waste plant:output:hot_water=yes or the x MW is you know it power=generator for the generator generator:source=waste generator:output:hot_water=yes or the x MW is you know it generator:method=combustion generator:type=boiler for the pipeline man_made=pipeline location=underground substance=heat Regards, Marc _______________________________________________ Tagging mailing list [email protected] https://lists.openstreetmap.org/listinfo/tagging