On Sun, Oct 28, 2012 at 01:55:34PM +0100, Alexandre Ratchov wrote:
> On Sat, Oct 27, 2012 at 03:14:07PM +0200, Alexandre Ratchov wrote:
> > Hi,
> > 
> > This diff is to use dedicated messages for flow control instead of
> > abusing clock tick messages and to enable flow control for MIDI.
> > There should be no change in behaviour, but this change is
> > necessary for future developpement of sndiod.
> > 
> > any regression? ok?
> > 
> 
> sorry; the previous diff is wrong, please consider the one
> below (thanks jsg@)

There seems to be some compat issue, before I restarted sndiod 44khz
audio was playing at what sounded like the system/hardware 48khz without
conversion.  After restarting sndiod it was fine though.

A quick midi test seems to reveal no problems, sysex messages still come
through, timing sounds right.

Reply via email to