On Sun, Oct 28, 2012 at 01:55:34PM +0100, Alexandre Ratchov wrote: > On Sat, Oct 27, 2012 at 03:14:07PM +0200, Alexandre Ratchov wrote: > > Hi, > > > > This diff is to use dedicated messages for flow control instead of > > abusing clock tick messages and to enable flow control for MIDI. > > There should be no change in behaviour, but this change is > > necessary for future developpement of sndiod. > > > > any regression? ok? > > > > sorry; the previous diff is wrong, please consider the one > below (thanks jsg@)
There seems to be some compat issue, before I restarted sndiod 44khz audio was playing at what sounded like the system/hardware 48khz without conversion. After restarting sndiod it was fine though. A quick midi test seems to reveal no problems, sysex messages still come through, timing sounds right.