You never told us what it looked like on your scope joe. Mark Wentowski Perry Hill Electronics 3836 Harrison Rd. Montgomery AL 36109 phone: (334)279-5622 fax: (334)273-9050 [EMAIL PROTECTED]
-----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Behalf Of Joe Tech2004 Sent: Wednesday, April 07, 2004 7:05 PM To: Email list for ELECTRONICS PROFESSIONALS only Subject: [Techs] Sanyo DS19630 / ch-19630-00 relay clicks on then off Sanyo DS19630 chassis 19630-00 mfd-1996 Original problem relay clicks on then off. found HOT (D1685) shorted. Replaced with a new (D1685) that says Sanyo on it even though I didn't order OEM. Fired with variac at 100v AC, B+ 80vdc and relay still clicked on then off. HOT ok with variac. Removed regulator (STR30135) which seems to check ok, B+ went to 139vdc relay still on then off. Turned variac down to 85v AC, B+ went down to 115vdc relay still on then off. Sounds to simple, what am I overlooking...??? Even If generic HOT that says Sanyo x-istor was not a good replacement, would it still react this way with regulator removed...??? No Print. Thanks "joe" Joes....Electronics �(Joe:Tech/2004) [EMAIL PROTECTED] Fax::509-479-2283 _______________________________________________ Tech Repair CD...order your just $49.00 plus shipping...One year of updates free. www.intrepid-video.com www.tech-repair.net Techs mailing list [EMAIL PROTECTED] http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com _______________________________________________ Tech Repair CD...order your just $49.00 plus shipping...One year of updates free. www.intrepid-video.com www.tech-repair.net Techs mailing list [EMAIL PROTECTED] http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com