Is that bolted down to a metal ? If so , should read zero
ohms !
Best: Eugene

LeRoy Westlund wrote:
> 
> Hi members,
> This Sharp micro-wave oven won't heat.
> Control panel counts down OK, but has no 115 A/C volts driving the high
> voltage transformer. The Primary interlock relay RY-2 is not activating.
> Also, the turn table does not turn.
> I found a fix in Jeff's Intrepid CD program that said to replace the
> Temperature  thermistor part # FH-HZA041WREO.
> I found the thermistor, but it measures 235K ohm across it. Do you think
> that reading is too high ? Shouldn't a good thermistor read much less then
> that ? Does anyone have one they could measure, to confirm that this part is
> bad. I hate to order one, if it won't fix the problem.
> 
> TIA,
> LLW
> 
> LeRoy Westlund
> Westlund TV & Electronics
> 97 North Main                                "Where there's a will,...
> Centerfield, UT 84622-0087           There's always a way."
> Ph./Fax  435-528-3822
> mailto:[EMAIL PROTECTED]
> 
> _______________________________________________
> Tech Repair CD...order your just $49.00 plus shipping...One year of updates free.
> www.intrepid-video.com www.tech-repair.net
> Techs mailing list
> [EMAIL PROTECTED]
> http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com

-- 
Head Witch Doctor and Chief Bottle Washer
Eugene Spooner , CET , AAS , NP
Eugene's Carry-In TV
1417 Eastway Drive
Charlotte , NC 28205
mailto:[EMAIL PROTECTED]

_______________________________________________
Tech Repair CD...order your just $49.00 plus shipping...One year of updates free.
www.intrepid-video.com www.tech-repair.net
Techs mailing list
[EMAIL PROTECTED]
http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com

Reply via email to