Is that bolted down to a metal ? If so , should read zero ohms ! Best: Eugene
LeRoy Westlund wrote: > > Hi members, > This Sharp micro-wave oven won't heat. > Control panel counts down OK, but has no 115 A/C volts driving the high > voltage transformer. The Primary interlock relay RY-2 is not activating. > Also, the turn table does not turn. > I found a fix in Jeff's Intrepid CD program that said to replace the > Temperature thermistor part # FH-HZA041WREO. > I found the thermistor, but it measures 235K ohm across it. Do you think > that reading is too high ? Shouldn't a good thermistor read much less then > that ? Does anyone have one they could measure, to confirm that this part is > bad. I hate to order one, if it won't fix the problem. > > TIA, > LLW > > LeRoy Westlund > Westlund TV & Electronics > 97 North Main "Where there's a will,... > Centerfield, UT 84622-0087 There's always a way." > Ph./Fax 435-528-3822 > mailto:[EMAIL PROTECTED] > > _______________________________________________ > Tech Repair CD...order your just $49.00 plus shipping...One year of updates free. > www.intrepid-video.com www.tech-repair.net > Techs mailing list > [EMAIL PROTECTED] > http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com -- Head Witch Doctor and Chief Bottle Washer Eugene Spooner , CET , AAS , NP Eugene's Carry-In TV 1417 Eastway Drive Charlotte , NC 28205 mailto:[EMAIL PROTECTED] _______________________________________________ Tech Repair CD...order your just $49.00 plus shipping...One year of updates free. www.intrepid-video.com www.tech-repair.net Techs mailing list [EMAIL PROTECTED] http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com