We have only deployed 983 in limited fashion, but I can't say that we've seen this. We haven't finished testing, but so far, with the exception of the web-based iperf feature, it has been pretty solid for us (certainly at least when it comes to the basics / in the connectivity department).
So it's attached but doesn't think it's attached? Did you test 826 and 832 before this? Did either of those ones work for you? -- Nathan -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Ian Fraser Sent: Saturday, March 18, 2017 1:42 PM To: [email protected] Subject: [Telrad] Stuck UE's on Build R983 Anyone seen this one yet ? EPC .00729 eNB .04013 CPE8K .983 UE connects and shows up in the EPC UE-Info list but it is not pingable and cannot access the Internet. Detach and it reattaches in a timely manner but the GUI looks like this http://my.jetscreenshot.com/29292/20170318-fx4t-37kb Power cycled it and same thing. Downgraded to 694 and connection works. Tried another 8K at the same location and had the same results with each respective version of code. Now running 694 it looks like this http://my.jetscreenshot.com/29292/20170318-rzb5-38kb Ian _______________________________________________ Telrad mailing list [email protected] http://lists.wispa.org/mailman/listinfo/telrad _______________________________________________ Telrad mailing list [email protected] http://lists.wispa.org/mailman/listinfo/telrad