Said,

Just a quick note about the HP 54720D. If you have 2 of the 4Gs plugins 
installed & are measuring a differential ECL signal; this combination yields
<2pS rms jitter. I spent many hours characterizing clock gen/dist circuits 
for the HP PARisc family of processors; periodic noise floor confirmation
was essential for high confidence results.

Regards,
Pete Rawson 