); SAEximRunCond expanded to false Errors-To: [EMAIL PROTECTED] Brooke Clarke wrote: > Hi: > > The DG535 Four Channel Digital Delay/Pulse Generator shows > Ext Clk Error on power up. > The obvious thing to do is turn the rear panel switch to INT, but after > powering up with the switch in either position the same error message appears. > > Connecting an external 10 MHz to the clock input and with the INT/EX switch > in > either position the same error is there. > > The on line manual does not have schematics. Any thoughts? > > Brooke
Is the longtailed pair Q502+ Q503 producing a 10MHz ECL level output signal? Bruce _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.