); SAEximRunCond expanded to false Errors-To: [EMAIL PROTECTED] The key is the gas tight connection between the surfaces. If moisture and/or oxygen can't get in the conection will remain true. Back in an earlier life in the telecommunications industry connections went from soldered to wire wrapped in the 70's. We were all distrustful of a 'twisted on' connection until it was explained to us. The proof was in the pudding (so to say) when after a year or two statistical analysis revealed that the post-install trouble rates plummeted with the advent of wire wrap, but after 10 years started creeping back up as the frame blocks reached the end of their reliable life as circuits were reterminated on those little square posts with the less than perfectly square corners...
____________________________________________________________________________________ Luggage? GPS? Comic books? Check out fitting gifts for grads at Yahoo! Search http://search.yahoo.com/search?fr=oni_on_mail&p=graduation+gifts&cs=bz _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.