); SAEximRunCond expanded to false Errors-To: [EMAIL PROTECTED] RETRY > > The Achilles' heel of this technique is the statistical temperature > > fluctuations experienced by individual resistors. > > ...
Seems debatable whether it's worth worrying about details like this when the EFC signal is just going to go straight into a 20K-100K resistor in the OCXO, isn't it? I just use a simple resistor network to drop the bipolar DC EFC control voltage from my 11729C to the level needed by the 10811A in my 8662A, and I have no problem making measurements at the 10811A's specified noise floor, at least from 100 Hz and beyond. I suppose 1/f and popcorn noise is still a concern, but surely that's dominated by the relatively-large resistance between the EFC control loop and the varactor. No? -- john, KE5FX _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.