); SAEximRunCond expanded to false Errors-To: [EMAIL PROTECTED] RETRY In a message dated 11/9/2007 07:50:26 Pacific Standard Time, [EMAIL PROTECTED] writes:
>Here is the question, I only have room for one counter, should it be a 5370B or a 53131A? Which >is more useful to measuring frequency variations? >Jeff Hi Jeff, In my opinion the 5370B is better for phase offset measurements, and the 53131A better for frequency measurements. The 5370B is not good at all for direct frequency measurements. The 53131A is not that good for phase measurements. bye, Said ************************************** See what's new at http://www.aol.com _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.