> -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of Matt Ettus > Sent: Thursday, December 13, 2007 8:25 PM > To: Discussion of precise time and frequency measurement > Subject: Re: [time-nuts] Super Regulator links > > Can you explain to me the use of fast recovery diodes if you > are going to put capacitors across them? > > Matt
We even use snubbers across Shottky and FRED rectifiers, in spite of what the vendor's litterature claims. Anything that is non linear in series with a magnetic structure (does not have to be a transformer, a trace or wire long enough would do) is a potential source of ringing and noise. Didier KO4BB _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.