> -----Original Message-----
> From: [EMAIL PROTECTED] 
> [mailto:[EMAIL PROTECTED] On Behalf Of Matt Ettus
> Sent: Thursday, December 13, 2007 8:25 PM
> To: Discussion of precise time and frequency measurement
> Subject: Re: [time-nuts] Super Regulator links
> 
> Can you explain to me the use of fast recovery diodes if you 
> are going to put capacitors across them?
> 
> Matt

We even use snubbers across Shottky and FRED rectifiers, in spite of what
the vendor's litterature claims. 
Anything that is non linear in series with a magnetic structure (does not
have to be a transformer, a trace or wire long enough would do) is a
potential source of ringing and noise.

Didier KO4BB


_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.