Very interesting thread. I have been following half distractedly the thread on leap second, while working on the firmware for my GPS Monitor. I am at version 0.1.2, and the second line of the display is now used to display RX Mode, Disciplining Mode, Temperature or DAC Voltage in succession, by pressing a push button. I am using my second prototype for that, the first prototype is still connected to the other TB.
This is working, then I glanced at the first prototype, running firmware 0.0.9, and it was alternating between "Normal" and "Leap Second Pending" . V0.0.9 is designed to alternate between the mode and warning flags when any is present. I had not been able to test that feature, because my Thunderbolts are all stabilized, surveyed and so forth. Well, I know now that works too :-) Unfortunately, v0.1.2 at the moment does not display flags at all :-( I have to decide what to do with the flags, I don't want to be displaying "Leap Second Pending" for 6 months, yet other flags may be important to display (like antenna disconnected or shorted). Didier KO4BB _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.