John - I did have to run it as Admin. I tried a few things on a Guest logon including a USB serial port but got the 0x02 error. Just clicking on the Lady Heather icon worked on the first try using a real serial port..
Your display is beautiful - you did good. Doug, W5JUV Lubbock -------------------------------------------------- From: "John Miles" <[email protected]> Sent: Wednesday, February 11, 2009 5:27 PM To: "Discussion of precise time and frequency measurement" <[email protected]> Subject: Re: [time-nuts] Initial release of Lady Heather for Windows > Thanks for the confirmation -- I don't believe anyone else has tried it on > Windows 7 before. Did you have to run it as admin? > > Christopher, I imagine there's either a WoW64 compatibility problem or > (more > likely) the unit you're using isn't 100% compatible with Trimble's TSIP > implementation for the Thunderbolt. It would be interesting to hear if > you > can try 64-bit Vista with a real Thunderbolt; otherwise there are too many > variables at play to make an educated guess as to what's going on in your > case. Error code 0x02 means that it found the serial port and opened it > correctly, but timed out trying to perform a read operation. > > -- john, KE5FX > >> -----Original Message----- >> From: [email protected] [mailto:[email protected]]on >> Behalf Of Doug Hutton >> Sent: Wednesday, February 11, 2009 2:08 PM >> To: Discussion of precise time and frequency measurement >> Subject: Re: [time-nuts] Initial release of Lady Heather for Windows >> >> >> I just downloaded and ran it on Windows 7 and it works fine on >> a group-buy Thunderbolt.. >> >> Doug Hutton >> >> >> -------------------------------------------------- >> From: "christopher hoover" <[email protected]> >> Sent: Wednesday, February 11, 2009 12:14 PM >> To: <[email protected]> >> Subject: Re: [time-nuts] Initial release of Lady Heather for Windows >> (JohnMiles) >> > >> > Is it known to run on Vista? How 'bout Vista x64? >> > >> > I'm trying on Vista x64 with a GPSTM (related but not actually >> > thunderbolt), >> > I get: >> > >> > Serial receive error, code 0x2. >> > > > > _______________________________________________ > time-nuts mailing list -- [email protected] > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.