Richard (Rick) Karlquist wrote:


Bob Camp wrote:
Hi

I think that if you dig into it, you will find that there is a polarized light process to orient the blank before the base plate is applied.

Unfortunately for the discussion at hand, the direction of maximum G sensitivity is still random relative to the mount.

Bob
KB8TQ

To clarify: the crystal PACKAGE (base plate) is randomly oriented in the 10811 casting. Therefore, it doesn't matter if the blank is positioned in some definite orientation with respect to the base plate.

Around the blanks rotational axis I assume. That should stay the same, right? It's just one rotational freedom and not three that is there.

Cheers,
Magnus