Jim I may be talking out of the wrong end of my digestive tract, but what timescale were you using for your measurements?
If you are seeing a continual drift with observations over an hour or two, I'd look to see what you have over 24 hours or more. Is it possible that the drift you are seeing is caused by regular diurnal variation in the temperature of the inner oven which the system cannot quite control enough. OTOH I could be barking up completely the wrong tree. Dave _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.