Maybe! But for the sake of clarity: I have been asking how HP/Symmetricom
manage to handle the regulation loop appearantly WITHOUT time constant
adaption/switching and with a fixed time constant that seems to be much too
high to start with for a cold OCXO.
Best regards
Ulrich Bangert
One answer might be the use of a second integrator. The HP5061 used
an analog second integrator, which was quite non trivial to implement
at the time. The 5071 also uses a second integrator, which is of
course digital. The oven control loop of the E1938A uses first and
second integrators (PID + I^2) to get the best of both worlds.
None of these use switched time constants.
Rick Karlquist N6RK
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.