> Unless one uses a 3 cornered hat technique or equivalnet one can only
> measure the relative stability of a pair of sources.
> What source was used as the reference in your measurements?

The measurements were made with an upgraded 5061A (Datum tube and
10811-60109).

I have used it to measure my GPS clock at 2.0E-12 at t=100s before, so it's
actually inside the 5071A limit there.  I don't know where its floor really
is but it appears to be much better than spec (as are most 5071As,
presumably).

-- john, KE5FX