Hi Brian, This is a classical crystal jump. Nothing one can do about it. Could have been internal to the crystal (stress-relief) or external (gamma particle hitting the crystal lattice etc). My 58503A does it every couple of days or so. Really messes with your ADEV performance... bye, Said In a message dated 1/26/2010 17:27:57 Pacific Standard Time, [email protected] writes:
The second drawing is a chart from Excel. The Z3801A 1 PPS was being compared against a HP5065A rubidium and this data is the 100 second averages record by TAC32. Note is shows a 200 nS jump too. The scale of the plot is in microseconds (I run a 10 uS offset for some long term drift experiments). I cannot remember what causes this from past discussions - it may be an oven regulator.... Brian - KD4FM _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.