the problem was in the syinthesizer board A1 , the xtal oscillator 12.63 was to much aging and was at the limit of pll , now I fixed this board , now the 12.63 signal is clear and loocked , before was very noisy . But seeme there are more problem , the signal now is very close to 5MHZ but there are some difference from my rubidium and my Z3805a
The 5 MHZ now is near 5 x 10-10   .

Now I need to ascertain , if there are more fault , or because I have an high performance tube , I need a degausser ??????

I will continue to study .

all suggestion will be appreciated

i5uxj

_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to