For this temp range, thermal shock or reversal should not be a problem. Neither is reversal, just use a (relatively) cheap h-bridge off epay... working out the water temp might be a problem? There will be no problem with h-bridges, as the Peltier junction has very small L-C values, ie not like a motor... Don
Jerome Peters > Does anybody know about using the same Peltier junction for both heating > and cooling? > I'm concerned about thermal/mechanical shock when changing the polarity > back-n-forth between hot and cold. Maybe there needs to be a controlled > ramp, if so then how do I figure out the rate? > > Why: > I'm in the process of building a small environmental chamber for my home > lab. The volume is ~30 liter, target temp range of 0C to 60C. For the > cooling side I am using water circulation (radiator, pump, reservoir & > water block) and Peltier junctions. At first I was planning to have two > separate systems, one for heating and one for cooling, but then I got to > thinking that using just the water and Peltier could be used for both. I > will be using a PID for temp control, and two TEC1-12726 Peltier Qcmax(w)= > ~240 $B"$(BT =0j > > > Regards, > Jerome > ----------------------------------------------------------------------------------- > This email message is for the sole use of the intended recipient(s) and > may contain > confidential information. Any unauthorized review, use, disclosure or > distribution > is prohibited. If you are not the intended recipient, please contact the > sender by > reply email and destroy all copies of the original message. > ----------------------------------------------------------------------------------- > > _______________________________________________ > time-nuts mailing list -- [email protected] > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. > -- "Neither the voice of authority nor the weight of reason and argument are as significant as experiment, for thence comes quiet to the mind." R. Bacon Dr. Don Latham AJ7LL Six Mile Systems LLP 17850 Six Mile Road POB 134 Huson, MT, 59846 VOX 406-626-4304 www.lightningforensics.com www.sixmilesystems.com _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.