Hi Bert, That is very interesting, thank you for sharing.
Didier KO4BB Sent from my BlackBerry Wireless thingy while I do other things... -----Original Message----- From: "Bert, VE2ZAZ" <[email protected]> Sender: [email protected] Date: Mon, 21 Mar 2011 10:11:04 To: <[email protected]> Reply-To: Discussion of precise time and frequency measurement <[email protected]> Subject: Re: [time-nuts] HP 3586A/B/C entirely referenced to 10MHz: A solution Hello Everyone, I have spent the last few weeks modifying the HP 3586 Selective Level Meter. The intent was to modify the unit and reference the SSB product detector stage to the internal reference. This would make the entire SLM locked to the 10MHz reference, whether internal or externally fed. I have completed the modification with satisfactory results. I use a DDS-Based Function Generator 16-pin IC and a small 8-pin PIC micro. For more detail, visit my website at http://ve2zaz.net/HP3586_AD5962/HP3586_AD5962.htm . This has been a very good exercise from a DDS perspective and I have learned a lot on the topic. I would be interested in hearing from those who proceed with the mod. Thanks, Bert, VE2ZAZ _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.