To all: I ran the "root eng ee info" on my two TS2100s, both were originally IRIG units but I upgraded them myself to GPS models...
Both my OCXO unit and TCXO unit reported "00000000" As for the parameters in my "timing / utils" directory, here's both models: OCXO (MTI 240-0530-D) --------------------- gain = -20 filter = 0.9995000 low = 0.0000000 (Manual says this isn't used, but figured I would post it) d/a = 0xa05d tfp 0 = 0xa005 tfp 6 & 7 = 0.9994965 TCXO ------------------- gain = 2 filter = 0.9500000 low = 0.0000000 d/a = 0x85c0 tfp 0 = 0x85a4 tfp 6 & 7 = 0.9499970 My OCXO model came from Yahoo!, it still has the asset sticker on the side. It was in free-run mode when I got it. As mentioned above, the OCXO is a MTI with the following info: Model: 240-0530-D PN: 010285-0530 If you want to see some hi-res images: http://www.rabel.org/archives/Images/TS2100/ Time to poke around the eng directory and see if I can fix that pesky offset compared to my other time servers... There used to be a command in the earlier firmware versions but it appears they removed it. remote refid st t when poll reach delay offset jitter ================================================================ +NET4501-1 .GPS. 1 u 37 64 17 0.714 -0.029 0.087 *NET4501-2 .GPS. 1 u - 64 77 0.820 -0.022 0.129 +PRAECIS .GPS. 1 u 61 64 37 0.712 0.052 0.058 -TS2100-1 .GPS. 1 u 63 64 37 4.937 -0.406 0.025 -TS2100-2 .GPS. 1 u - 64 77 4.976 -0.366 0.046 The "root / eng / timing / offset" shows: Current offset : -5 at offset unit (100ns) I wonder if that might do the trick? Hmmm... _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.