When I got my first unit I hooked it up to my protoboard power supply which is
rated at 15 volts 0.5 amps and 5 volts 1 amp. I was annoyed that it took about
10 minutes to lock up until I realized the 15 volt supply was down near 11.5
volts. Oops. Substituting my small B&K bench supply (good for up to 3 amps)
resulted in a lock in under a couple of minutes. Perhaps my unit's internal
adjustments are still just about right. It would be nice to get the alignment
procedure for the thing, but I suppose, fat chance of that.
Peter
On 1/19/2012 6:45 PM, gonzo . wrote:
Experiment for the day.
I thought I'd follow Dons quote and see how tolerant my unit is.
My benchmark is at 15.5V it locks in about 3min.
I backed off the supply to 10.8V and the lock time (from cold) is 8min.
I thought this was interesting given several people report they are unable to
get a lock when running lower voltage.
ian
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.
-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1416 / Virus Database: 2109/4754 - Release Date: 01/19/12
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.