Over at http://tf.nist.gov/tf-cgi/wwvbmonitor_e.cgi there is a "relative field strength" plot for each of the monitoring stations. I'm trying to correlate LaCrosse with my own measurements in St. Paul (AGC voltage in my Spectracom 8164) and it's very bothersome that this graph has no scale and no origin. The unit is said to be uV/m. Does anyone here happen to know what the evident top rail value is? It often hits it during the dark-path period. And the magnitude of a vertical tick? I suppose it's logarithmic.

The 8164 manual says that AGC 2.0V corresponds to 100uV/m at a properly oriented antenna.

I got both the 8170 and the 8164 going last night, after finding the other 8206 antenna[1], still mounted in the attic of the garage. So I have one outdoors (in the back yard, up 10 feet on a PVC pipe), but with a long and maybe lossy feed line, and the other one nearby but indoors. Today they both seem quite happy (AGC 1.3V), even though LaCrosse is "unreadable".

[1] "Engine #3 found on right wing after brief search."

_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to