Set the scope sweep speed to 10 milliseconds per division and then even a dull scope is easy to see. You are looking for trigger events from the 1PPS, not the 1PPS itself.

John  WA4WDL

--------------------------------------------------
From: "C. Turner" <[email protected]>
Sent: Monday, July 23, 2012 2:26 PM
To: <[email protected]>
Subject: Re: [time-nuts] Trimble T Lassen 2 -suitableantenna....advice.....questions

My old '465 will trigger on the 1pps, but it's far easier to see the trigger LED flash than finesse the brightness/sweep to make it visible - something possible only on a 'scope with a decently bright tube.

Another cheap/easy trick to detect the 1pps pulse is simply to "listen" to it with an audio amplifier.

While it can be heard on my Tbolt and '3801 with just a headphone connected, a cheap audio amplifier works better, stretching the pulse out and making an obvious "tick" at the 1 PPS rate. I suppose that a diode/cap (1N914/1000pf) could be used to further stretch it...

Clint


_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.



_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.