On 1/9/2013 12:48 PM, Azelio Boriani wrote:
and don't forget the PM6681 (50pS)

The PM6681 was sold by Fluke/Philips. The same counter is also occasionally seen as the Pendulum CNT-81. Additional good features: small, light, and quiet.


On Wed, Jan 9, 2013 at 7:29 PM, Magnus Danielson<mag...@rubidium.dyndns.org
wrote:
On 01/09/2013 05:39 AM, Ed Palmer wrote:

In the past there has been much discussion on this list regarding the
relative strengths and weaknesses of the 5370 (20ps resolution) and the
5371/5372 (150ps resolution) units. There are other units that have even
better resolution, but they tend to be pricey and/or more specialized.

The 5371/5372 has a 200 ps resolution. They where designed to allow
extension to 100 ps resolution. The FLASH-interpolators have 200 ps steps,
sufficiently good trigger such that you get 150 ps resolution performance
on the white-noise limit.


Cheers,
Magnus



_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to