Thank you for these additional informations, Bert ! regards Arnold
Am 25.05.2013 21:58, schrieb [email protected]: > Questions have come up on the recent release of the Shera code. All > software commands with the exception of Auto N get lost in case of power > failure. > Auto N is stored in EEPROM. After power fail Dip switches take over. Alpha > filter can be activated with software commands or switch #5. #5 can be DAC > Hold or Alpha present compiled code is Alpha. An open switch on #5 is > Alpha on. In manual or auto N Alpha is first engaged in filter 4 position. If > > auto N is enabled and there is a power fail and #5 is open code will run up > to the value selected by the Dip switches and once it reaches 4 enables > Alpha filter. Also some status commands have been added listed below > Bert Kehren > > > ;Status bits (RS232): > ; bits > ; 0-7 N value as always > ; +10 glitch detected > ; +20 alpha filter actually used > ; +50 alpha filter enabled > ; +100 "unlock" LED on > _______________________________________________ > time-nuts mailing list -- [email protected] > To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.