This kind of problem is almost always the electrolytic filter capacitors in the power supply shorting. Sometimes they take the diodes with them. the repair is easy. I often preemptively replace all the power supply electrolytics in old devices.

hld

On 8/26/2013 9:25 PM, paul wrote:
Greetings Time Nuts!

I used to work for an electric utility and, around the Millennium,
acquired a used 468-DC, an FTM II, and the requisite GPS to GOES
antenna. The FTM was the first to no longer power on, and now the 468-DC
blows the main fuse whenever it is powered on. I am wondering if:

        * it's worth someone fixing it
        * how it compares with, for example, the Sure Electronics MB-CM12118
Mini USB & Bluetooth Interface GPS Demo Board (which you reviewed
favorably). I know the 468-DC is built much better, but does it keep
better time?