Thanks Gotz 2 and 3 grounded works fine for me too, although I still have one unit that insists on flashing the ON light rather than bringing it on solid. In all other respects both units seem to match. Two more should be arriving sometime in the next couple of weeks so will see how they match up. Just for reference, pin 13 is also a ground connection so if just pushing wires into the connector it might be convenient to use both grounds. Regards Nigel GM8PZR In a message dated 02/11/2014 17:58:12 GMT Standard Time, go...@g-romahn.de writes:
Am 02.11.2014 15:08, : > Ooh err, whoops, and oh dear !! > > Arthur, I've only just had a chance to look at your latest photos, and > unless I've really got my wires crossed, if you'll pardon the expression:-), > your links on J5 are not shown on pins 2, 10, 12, and 15, but on pins 4, 6, > 11, and 13. > > As far as I'm aware the numbering from the front of that connector as shown > starts in the top right hand corner and every row is numbered right to > left. > That's certainly how mine are numbered anyway, and I wired them > accordingly, and it worked, so where the heck does that leave us now?:-) > -------------------------- thanks Nigel for detecting this glitch. I removed all jumpers now and tested some reasonable new/old combinations resulting in very simple scheme: it seems to be sufficient to connect pin2 and pin3 to pin8 (ground). Numbering as provided by Nigel and markings on my 15 pin-plug. Götz _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.