Le 27 janv. 2016 18:04, "Martin Burnicki" <[email protected]> a écrit : > > Magnus Danielson wrote: > > Hi, > > > > On 01/26/2016 11:46 PM, Martin Burnicki wrote: > >> Paul Boven wrote: > >>> Hi everyone, > >>> > >>> Has anyone else seen GPS time jump by -13.7 usec today?
Good morning, I have subscribed to this list following this incident as far as it was the first of the few results of search in Google for three days ago. On my linux platform of hundreds serveurs, I had incident because of this, on servers which only use of ptp. I have two sources grand master clock one I control (a meinberg appliance) and act as passive and the second is just a Cisco relaying the ptp stream from the market. As a side effect of those glitch in the GPS matrix, the utc_valid_flag was not anymore set in the stream of the primary master clock, just before my secondary starts to become active (loss of primary stream) which leads to linux server ptp slave to readjust of +36 seconds and jump backward -36 seconds as far as the flags was coming back. Am I the only one who suffered the loss of the utc_valid_flag in ptp stream ? And what appliance would behave like this ? As far I can tell my secondary meinberg appliance aside a few oscillator recalibration message in the console log behaved very nicely. But I have no view of the primary master source and kind of hardware they use. Thank you in advance for your answer. -- Netmonk _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.