Hmmm, yes, you're absolutely right. Now I'm confused!
Peter
On 1 January 2017 at 16:21, Deirdre O'Byrne <[email protected]> wrote:
> Didn't the DUT1 code change from -0.4s during the minute starting 23:58:00
> to +0.6s during the minute starting 23:59:00?
>
> On 1 January 2017 at 16:06, Peter Vince <[email protected]> wrote:
>
> > Hi Deirdre,
> >
> > Well done getting such a clear recording! Yes, the leap-second is
> > effectively inserted after the DUT1 code on MSF as you say, even though
> > that isn't crystal clear from the MSF spec document that David linked to.
> > The DUT1 codes refer to the "current" minute, whilst all the rest of the
> > time and date information refers to the next minute epoch!
> >
> > Peter
>
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.