I should have mentioned this in the original post - the measurements were not taken on the same cable length. Beware, and consult paper.
Ole On Fri, Jan 13, 2017 at 7:52 AM, Ole Petter Ronningen <[email protected] > wrote: > Hi, all > > The question of phase shifts in cables pops up every now and then on this > list - I stumbled across a good table of measured phase shifts with > temperature in different cable types in this paper: > http://www.ira.inaf.it/eratec/gothenburg/presentations/ERATEC_2014_ > PresentationWSchaefer.pdf that I though would be of interest to others. > > A quick summary given below, see pdf for full details. Lots of other > interesting stuff in there also. > > Values in ppm/K, for 10 Mhz except when otherwise stated. (The paper gives > values for 5, 10 and 100Mhz) > > Huber-Suhner Multiflex 141: -6 > RG-223: -131.9 > Semiflex Cable: -11.5 > Huber-Suhner: -8.6 > Times Microwave LMR-240: -3.4 > Times Microwave SFT-205: 7.7 > Meggitt 2T693 SiO2: 30.6 > Andrew FSJ-1 (@5Mhz): 25 > Andrew FSJ-4 (@5Mhz): 10 > Andrew LDF-1P-50-42: 2.8 > Andrew LDF4-50A: 4.7 > Times Microwave TF4FLEX (@100Mhz):6.4 > Phasetrack PT210 (@100Mhz): 2 > > Ole > _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.