While playing with the RFTG-m GPSO I tried using a couple of RS-422 to RS-232 
converters.  These converters can be externally powered or "self-powered" by 
the RS-232 signals.

Both units worked fine as long as the RFTG was only sending the 22 character 
ASCII time code message once per second.  But when the RFTG was sending binary 
data along with the time code message they flaked out.  Apparently the 
converters power generator can't generate enough power when they are handling a 
lot of data.

One of the converters I tried was made by Hexin.  The other was a no-name 
Chinese mystery unit.  Also some USB serial port dongles can't properly power 
the converters no matter what data they are processing.