I am in the process of adding X72 support to Lady Heather.  The X72 
documentation (and the protocol used) is rather horrendous.   The available 
docs are rather old and crusty.  Does anybody have anything newer than the 
stuff on Symmetricoms web site... particularly for the latest firmware that 
supports disciplining via the 1PPS input.  I did find a manual for a device 
that uses a newer X72 that provides some clues.

Also, does anybody have any info on what the values returned by the "w" health 
command are.  The "w" command returns a list of around 27 values (in the form 
of "id_string: hex_val"  where id_string is a variable name and hex_val is the 
value in ASCII hex...  even floating point numbers are reported in hex (idiots! 
... the firmware has a routine for properly printing floating point values).  
Some of the variable names are easy to figure out, but others are rather 
cryptic.